TankBoost | Factory Reset of Control Unit
Your unit is pre-set with its operating parameters during assembly and testing.
If your unit is failing to operate and if instructed to do so by the Salamander Pumps Tech Desk team, please follow these instructions to reset your unit:
Press and hold ▲ + ▼ + I/O (power button) together until ‘nc’ flashes on the screen.
Press I/O to display ‘E00’ flashing on the screen.
Press I/O to display ‘ct0’ flashing on the screen.
Press I/O to display ‘dt0’ flashing on the screen.
Press I/O to display ‘AE1’ flashing on the screen.
Press I/O to display ‘Ar0’ flashing on the screen.
Press I/O to display ‘P0.0’ flashing on the screen.
Press I/O to display ‘c20’ flashing on the screen.
Press I/O to display ‘tE0’ flashing on the screen.
Press I/O to display ‘H00’ flashing on the screen.
Press I/O to display ‘r50’ flashing on the screen.
Press ▲ to display ‘r51’ flashing on the screen.
Press I/O to confirm – ‘OFF’ will display on the screen solid.
Press and hold ▲ until the display flashes ‘1.0’ – ‘bar’ to the right of the screen & ‘START PRESS.’ will show a green light.
Press ▲ until you reach 2.0 – press I/O to confirm.
Press and hold ▼ until the display flashes ‘3.0’ – ‘bar’ to the right of the screen & ‘STOP’ will show a green light.
Press ▼ until you reach 2.8 – press I/O to confirm. Press and hold ‘A’ until the display flashes ‘0.0’ – ‘A’ to the right of the screen will show a green light.
Press ▲ until you reach 4.8 – press I/O to confirm.
The screen will now display ‘OFF’ – The factory settings have now been restored.
Restart the unit by pressing I/O.
Factory Reset Settings
STOP | START | A |
2.0 | 2.8 | 4.8 |
Learn more about TankBoost troubleshooting from the Installation Guide.